Aluminium Column Cladding RFQ Checklist: Survey, Profiles and Junctions

An aluminium column cladding RFQ should define the measured structure, the intended finished profile, the vertical and horizontal joint layout, the head and base junctions, and every service or access point. Send a plan, elevations, sections, a column schedule and the current site-survey status. Mark dimensions that are confirmed, assumed or still to be verified.

The aim is to give every bidder the same geometric and coordination basis. It is not to approve the cladding material, support system, structural connection, fire strategy or project tolerances. Those decisions remain subject to the project specification, selected system and responsible design parties.

Illustrative aluminium column cladding with coordinated joints and junctions
Illustrative architectural scene. It is not a completed project, product sample or approved cladding detail.

Separate the structural column from the finished architectural profile

Column cladding is a visible enclosure around a structural column or another approved support arrangement. The structural column may be circular, rectangular, polygonal or irregular, while the finished cover may follow it closely or create a different architectural profile. A finished round column, for example, does not prove that the concealed structure is round.

Show both conditions. Record the structural size and position as one layer, then identify the intended finished outline, height and reference axes as another. If the cladding must align with a wall grid, ceiling joint, entrance axis or floor pattern, include that control line on the RFQ drawings.

The website’s aluminum column cladding page introduces round, tapered and shaped profiles together with joint, head and base questions. This guide expands the documentation process without defining a product specification.

Use one column schedule for every quotation

RFQ check What to show Why it matters
Column identity Building, level, grid reference, column number and quantity of each type Prevents similar-looking columns in different locations from being priced as one condition.
Survey status Survey date, surveyed area, datum and dimensions that remain unverified Separates measured information from design assumptions.
Concealed structure Structural outline, orientation, offsets and known obstructions Establishes the basis around which the architectural enclosure must be coordinated.
Finished profile Round, square, rectangular, tapered, faceted or other controlled outline Defines the visible geometry without implying that it matches the structure behind it.
Joint setting-out Vertical seam positions, horizontal break levels, reveal intent and alignment axes Makes the visual rhythm and panel divisions comparable between bids.
Head and base Ceiling, soffit, floor, skirting, plinth and adjacent-finish junctions Identifies closures and interfaces that a simple height and perimeter cannot describe.
Services and access Outlets, switches, signage, lighting, grilles, access panels and removable zones Prevents visible devices or maintenance needs from being discovered after the layout is fixed.
Support boundary Available substrate information and responsibility for secondary support Avoids assuming an unshown fixing surface or responsibility split.
Finish control Finish reference, visible-face direction, sample reference and adjacent materials Keeps appearance decisions tied to the same controlled reference.
Revision control Drawing numbers, issue date and a list of assumptions, exclusions and open items Ensures bidders respond to the same information package.

This schedule controls information. It does not establish engineering adequacy or supplier capability.

1. Establish the survey basis and datums

Start with a plan showing the column centreline or setting-out axes, nearby walls and the relevant floor or ceiling grid. Add elevations and sections that show the vertical extent. State whether dimensions come from design drawings, a completed site survey or a preliminary check.

For existing work, record conditions that can affect the enclosure: changes in section, offsets, surface irregularities, adjacent finishes, embedded devices and zones that could not be measured. Photographs can help explain a condition, but they should be keyed to the drawing and should not replace dimensions.

The current UFGS 07 42 63 Fabricated Wall Panel Assemblies is a U.S. wall-panel specification, not a column-cover specification for a UAE or Saudi project. It is useful here only as a documentation example: it calls for field verification of framing and opening dimensions before fabrication information is finalised and for penetrations to be coordinated with seam locations.

2. Define the finished profile independently

Provide a dimensioned plan section for each column type. Name the intended profile and show its orientation. If a square or rectangular cover must align with the building grid, mark the controlling face or axis. If a circular or curved cover must meet a straight wall, show the transition rather than leaving it to a perspective image.

For tapered, flared, faceted or changing profiles, add sections at the base, middle and head, plus any level where geometry changes. Do not reduce a changing profile to one diameter or width. Ask the bidder to identify any geometric assumption used to prepare the quotation.

PAC-CLAD’s metal column covers page is a manufacturer-specific example showing that round and square forms can use different joint expressions. Gordon’s architectural metal column covers page shows additional curved, oblong and custom shapes. Neither source defines what this website supplies; together they show why the selected profile and joint intent need to be stated rather than inferred.

3. Set vertical and horizontal joints deliberately

Draw the vertical seam positions in plan and elevation. A seam may be aligned with a wall, concealed from the main view, centred on an architectural axis or expressed as part of the design. State the intent so bidders do not choose different orientations for the same column.

Show horizontal joint levels and how they relate to floor lines, skirtings, ceiling breaks, doors, wall panels and other visible datums. If the column spans more than one storey, distinguish the architectural joint rhythm from movement, installation and support requirements that still require project-specific design.

Do not label an unconfirmed detail as “seamless.” Instead, show where joints are permitted, where they should align and which joint type remains to be proposed. Ask the bidder to return a marked-up elevation with the assumed panel divisions.

Illustrative survey and drawing review for round and square column profiles
Illustrative survey coordination. The linework and tools do not represent an approved drawing or recorded site measurement.

4. Draw the head, base and adjacent finishes

The base may meet a finished floor, raised floor, skirting, stone plinth or another protective finish. The head may stop below a ceiling, pass through it, meet a soffit or terminate at a feature band. Show each condition with a referenced section.

Identify the visible edge, gap or trim intent without inventing a dimension that the project has not approved. Where the floor or ceiling level varies, state the datum and show the expected adjustment zone. If wet cleaning, impact exposure or another operational condition affects the base, record the condition for the project team to evaluate; do not assume a performance solution.

Adjacent wall panels, glazing, doors, balustrades and ceilings should be shown on the same interface drawing. A generic “typical” detail is insufficient when different sides of one column meet different materials.

5. Coordinate services, signage and maintenance access

List every visible device associated with the column: outlets, switches, card readers, signs, speakers, lights, grilles, control panels and other project-specific items. Show the face, centreline and mounting zone for each item, together with the responsible trade and current coordination status.

If concealed equipment, valves or connections require future access, show the access location and route. A panel joint does not automatically provide a safe or practical access method. Ask the bidder to state the proposed removable area, necessary clearance and support assumptions, subject to project review.

Gordon’s manufacturer page includes product-specific access-panel options. That does not prove compatibility with another system; it demonstrates why access must be declared in the RFQ instead of added after the visible joint layout is agreed.

6. Make assumptions and site verification visible

Do not mix verified and preliminary dimensions in one schedule without labels. Use a clear status such as surveyed, design dimension, to be verified or by others. Add the survey date and drawing revision, especially where structural work or adjacent finishes are still changing.

Avoid inventing a universal tolerance. The allowable deviation and adjustment method depend on the project documents, geometry, support concept and selected system. Ask the responsible parties to define acceptance criteria, and require bidders to list the allowances or assumptions used in their proposals.

Before fabrication release, the project should confirm which dimensions require a final site check, who performs it, and how discrepancies are recorded and approved. A quotation based on preliminary information should remain visibly preliminary.

Illustrative aluminium column cladding RFQ package with profile samples and drawings
Illustrative RFQ package. The mockups and linework do not represent supplier products, approved details or certification.

7. Ask for a controlled return schedule

Require each bidder to return the proposed profile basis, panel divisions, joint intent, head and base approach, service-opening responsibility, access assumptions, support boundary and information still needed. Ask for exceptions to be listed against the same drawing revision.

Do not compare offers only by total surface area or price. First normalise the scope: the same column count, same profile, same height, same interfaces, same device openings and same site-verification status. Commercial comparison becomes more useful after the geometric and responsibility basis is aligned.

Copy-ready RFQ wording

Adapt this wording to the project:

Please quote the aluminium column cladding against the attached column schedule, plans, elevations, sections and survey record. Distinguish the concealed structural geometry from the required finished profile. Mark the assumed vertical and horizontal joints, head and base junctions, service openings, access requirements, support-interface assumptions and dimensions requiring site verification. Return a separate list of inclusions, exclusions, assumptions, exceptions and information required before fabrication release.

This request asks for a coordinated proposal. It does not approve the proposed assembly or its engineering.

Red flags before sending the RFQ

  • The enquiry gives only column height and perimeter, with no plan section.
  • Structural dimensions and finished dimensions are mixed in one unlabeled sketch.
  • Round, square, tapered and irregular columns are counted as one type.
  • Vertical seam orientation is left to each bidder.
  • Horizontal joints do not reference floor, ceiling or wall-panel datums.
  • Head and base conditions are described as “typical” despite different adjacent finishes.
  • Signs, outlets or access needs appear in photographs but not on the drawings.
  • No one is assigned to verify concealed structure or final site dimensions.
  • The finish reference differs between the drawing, sample and schedule.
  • Quotations are based on different drawing revisions or hidden assumptions.

Frequently asked questions

Is the structural column diameter enough for a round cover quotation?

No. The quotation also needs the intended finished diameter or profile, centreline and clear relationship to the concealed structure. The support arrangement, joints, head, base and adjacent finishes still need to be defined or listed as assumptions.

Should column joints be hidden from the main view?

That may be an architectural preference, but it is not a universal rule. Show the primary viewpoints, grid and adjacent joints, then state the desired orientation. The proposed arrangement remains subject to system and project review.

Can an existing column be measured only with photographs?

Photographs help record context but do not replace a controlled survey. Use dimensions, datums and keyed locations, and mark inaccessible or uncertain areas for later verification.

What files should accompany the enquiry?

Send the current plan, column schedule, dimensioned plan sections, elevations, head and base details, finish reference, device and access layout, site photos, survey status, project location, quantities and revision register. Mark every unresolved item and request a separate assumptions schedule.

For application context, review aluminum column cladding. For formed panel context, see folded aluminium cladding. When the coordinated package is ready, submit a project enquiry with the drawings, quantities and project location.

Reference sources

These sources illustrate coordination questions. The actual project specification, responsible design team, selected cladding system and relevant local authority determine the applicable requirements.